Summary
CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric PowerLogic™ P7 Affected: Version V02.003.001.000 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9718",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-25T15:50:42.425510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-25T15:51:23.849Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 P7",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version V02.003.001.000 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service."
            }
          ],
          "value": "CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-617",
              "description": "CWE-617 Reachable assertion",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-25T15:07:23.973Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-160-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-9718",
    "datePublished": "2026-06-25T15:07:23.973Z",
    "dateReserved": "2026-05-27T16:02:13.186Z",
    "dateUpdated": "2026-06-25T15:51:23.849Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9717 (GCVE-0-2026-9717)

Vulnerability from cvelistv5 – Published: 2026-06-25 15:05 – Updated: 2026-06-25 15:50
VLAI?
Summary
CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.
CWE
  • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
Assigner
Impacted products
Vendor Product Version
Schneider Electric PowerLogic™ P7 Affected: Version V02.003.001.000 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9717",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-25T15:50:24.128307Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-25T15:50:30.499Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 P7",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version V02.003.001.000 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-78 Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service."
            }
          ],
          "value": "CWE-78 Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-25T15:05:36.423Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-160-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-9717",
    "datePublished": "2026-06-25T15:05:36.423Z",
    "dateReserved": "2026-05-27T16:02:10.875Z",
    "dateUpdated": "2026-06-25T15:50:30.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-9716 (GCVE-0-2026-9716)

Vulnerability from cvelistv5 – Published: 2026-06-25 15:02 – Updated: 2026-06-25 15:49
VLAI?
Summary
CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.
CWE
  • CWE-476 - NULL pointer dereference
Assigner
Impacted products
Vendor Product Version
Schneider Electric PowerLogic™ P7 Affected: Version V02.003.001.000 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-9716",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-25T15:49:53.446856Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-25T15:49:59.528Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic\u2122 P7",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version V02.003.001.000 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device\u2019s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces."
            }
          ],
          "value": "CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device\u2019s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476 NULL pointer dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-25T15:02:28.169Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-160-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2026-9716",
    "datePublished": "2026-06-25T15:02:28.169Z",
    "dateReserved": "2026-05-27T16:02:10.007Z",
    "dateUpdated": "2026-06-25T15:49:59.528Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}