Search criteria

3676 vulnerabilities

CVE-2026-6807 (GCVE-0-2026-6807)

Vulnerability from cvelistv5 – Published: 2026-04-28 17:41 – Updated: 2026-04-29 15:12 Unsupported When Assigned
VLAI?
Title
NSA GRASSMARLIN Improper Restriction of XML External Entity Reference
Summary
A vulnerability in GRASSMARLIN v3.2.1 allows crafted session data to trigger improper handling of XML input, which may result in unintended exposure of sensitive information. The flaw stems from insufficient hardening of the XML parsing process.
CWE
Assigner
Impacted products
Vendor Product Version
NSA GRASSMARLIN Affected: All versions
Create a notification for this product.
Credits
Grady DeRosa reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-6807",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-29T13:40:03.937436Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-29T15:12:21.569Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GRASSMARLIN",
          "vendor": "NSA",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Grady DeRosa reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in GRASSMARLIN v3.2.1 allows crafted session data to \ntrigger improper handling of XML input, which may result in unintended \nexposure of sensitive information. The flaw stems from insufficient \nhardening of the XML parsing process."
            }
          ],
          "value": "A vulnerability in GRASSMARLIN v3.2.1 allows crafted session data to \ntrigger improper handling of XML input, which may result in unintended \nexposure of sensitive information. The flaw stems from insufficient \nhardening of the XML parsing process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-28T17:41:13.480Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-118-01"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-118-01.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-118-01",
        "discovery": "EXTERNAL"
      },
      "tags": [
        "unsupported-when-assigned"
      ],
      "title": "NSA GRASSMARLIN Improper Restriction of XML External Entity Reference",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "NSA has indicated that the GRASSMARLIN project has reached end-of-life \nstatus as of 2017 and is no longer supported. The project is archived, \nand no patches or further updates are planned or expected."
            }
          ],
          "value": "NSA has indicated that the GRASSMARLIN project has reached end-of-life \nstatus as of 2017 and is no longer supported. The project is archived, \nand no patches or further updates are planned or expected."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-6807",
    "datePublished": "2026-04-28T17:41:13.480Z",
    "dateReserved": "2026-04-21T16:01:40.334Z",
    "dateUpdated": "2026-04-29T15:12:21.569Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-3893 (GCVE-0-2026-3893)

Vulnerability from cvelistv5 – Published: 2026-04-28 17:34 – Updated: 2026-04-29 15:12
VLAI?
Title
Carlson Software VASCO-B GNSS Receiver Missing Authentication for Critical Function
Summary
The Carlson VASCO-B GNSS Receiver lacks an authentication mechanism, allowing an attacker with network access to directly access and modify its configuration and operational functions without needing credentials.
CWE
Assigner
Impacted products
Vendor Product Version
Carlson Software VASCO-B GNSS Receiver Affected: 0 , < 1.4.0 (custom)
Unaffected: 1.4.0
Create a notification for this product.
Credits
Souvik Kandar reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-3893",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-29T13:39:45.800186Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-29T15:12:29.585Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "VASCO-B GNSS Receiver",
          "vendor": "Carlson Software",
          "versions": [
            {
              "lessThan": "1.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "1.4.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Souvik Kandar reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The Carlson VASCO-B GNSS Receiver lacks an authentication mechanism, \nallowing an attacker with network access to directly access and modify \nits configuration and operational functions without needing credentials."
            }
          ],
          "value": "The Carlson VASCO-B GNSS Receiver lacks an authentication mechanism, \nallowing an attacker with network access to directly access and modify \nits configuration and operational functions without needing credentials."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-28T17:34:56.130Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.carlsonsw.com/support-and-training/"
        },
        {
          "url": "https://www.cve.org/CVERecord?id=CVE-2026-3893"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-113-02.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\nCarlson Software recommends users update to Version 1.4.0 or greater. \nFor more information contact Carlson Software \nhttps://www.carlsonsw.com/support-and-training/\u003c/div\u003e"
            }
          ],
          "value": "Carlson Software recommends users update to Version 1.4.0 or greater. \nFor more information contact Carlson Software \nhttps://www.carlsonsw.com/support-and-training/"
        }
      ],
      "source": {
        "advisory": "ICSA-26-113-02",
        "discovery": "EXTERNAL"
      },
      "title": "Carlson Software VASCO-B GNSS Receiver Missing Authentication for Critical Function",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-3893",
    "datePublished": "2026-04-28T17:34:56.130Z",
    "dateReserved": "2026-03-10T16:52:36.791Z",
    "dateUpdated": "2026-04-29T15:12:29.585Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-20766 (GCVE-0-2026-20766)

Vulnerability from cvelistv5 – Published: 2026-04-27 23:45 – Updated: 2026-04-28 14:39
VLAI?
Title
Milesight Cameras Heap-based Buffer Overflow
Summary
An out-of-bounds memory access vulnerability exists in specific firmware versions of Milesight AIOT cameras.
CWE
Assigner
Impacted products
Vendor Product Version
Milesight MS-Cxx63-PD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx64-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx73-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx75-xxPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx83-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx74-PA Affected: 0 , ≤ 3x.8.0.3-r11 (custom)
Create a notification for this product.
    Milesight MS-C8477-HPG1 Affected: 0 , ≤ 63.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C8477-PC Affected: 0 , ≤ 48.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C5321-FPE Affected: 0 , ≤ 62.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx52-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxGPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx61-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx67-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx71-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx41-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx76-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx65-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-CQxx31-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx68-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx72-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-NxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxC Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxG Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxH Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxT Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight PMC8266-FPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PMC8266-FGPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PM3322-E Affected: 0 , ≤ PI_61.8.0.3_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5510-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r7 (custom)
Create a notification for this product.
    Milesight TS5510-GH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS5511-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS2966-X12TPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS2966-X12TVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RWE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4WE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight MS-C2964-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2972-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-RFLWPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TGPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC/W Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2867-X5TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2961-X12TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS8266-FPC/P Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5361-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxxGOPC Affected: 0 , ≤ 45.8.0.2-AIoT-r4 (custom)
Create a notification for this product.
    Milesight SC211 Affected: 0 , ≤ C_21.1.0.8-r4 (custom)
Create a notification for this product.
    Milesight SP111 Affected: 0 , ≤ 52.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx66-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
Credits
Souvik Kandar reported these vulnerabilities to CISA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-20766",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-28T14:37:23.854997Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-28T14:39:17.799Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx63-PD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx64-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx73-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx75-xxPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx83-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx74-PA",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "3x.8.0.3-r11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-HPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-PC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "48.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5321-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "62.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx52-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx61-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx67-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx71-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx41-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx76-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx65-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx31-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx68-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-NxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxG",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxT",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PM3322-E",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PI_61.8.0.3_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5511-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RWE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4WE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2964-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2972-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-RFLWPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TGPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC/W",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2867-X5TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2961-X12TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-FPC/P",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5361-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxxGOPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "45.8.0.2-AIoT-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SC211",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "C_21.1.0.8-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SP111",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "52.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Souvik Kandar reported these vulnerabilities to CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan\u003eAn out-of-bounds memory access vulnerability exists in specific firmware versions of Milesight AIOT cameras.\u003c/span\u003e"
            }
          ],
          "value": "An out-of-bounds memory access vulnerability exists in specific firmware versions of Milesight AIOT cameras."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-27T23:45:52.896Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-113-03.json"
        },
        {
          "url": "https://www.milesight.com/support/download/firmware"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u0026nbsp;\u003cbr\u003e\u003ca href=\"https://www.milesight.com/support/download/firmware\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/support/download/firmware\u003c/a\u003e\u003c/p\u003e\u003cp\u003eMS-Cxx63-PD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx64-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx73-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx75-xxPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx83-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx74-PA: Update to 3x.8.0.3-r13\u003c/p\u003e\u003cp\u003eMS-C8477-HPG1: Update to 63.8.0.4-r4\u003c/p\u003e\u003cp\u003e\u0026nbsp;MS-C8477-PC: Update to 48.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C5321-FPE: Update to 62.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx76-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx65-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u0026nbsp;\u003c/p\u003e\u003cp\u003eMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003ePMC8266-FPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePMC8266-FGPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePM3322-E: Update to PI_61.8.0.3-r5\u003c/p\u003e\u003cp\u003eTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u0026nbsp;\u003c/p\u003e\u003cp\u003eTS5366-X12RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5510-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5510-GH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5511-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS2966-X12TPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS2966-X12TVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RWE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4WE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C2964-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2972-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TGPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC/W: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2867-X5TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2961-X12TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS8266-FPC/P: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5361-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\u003c/p\u003e\u003cp\u003eSC211: Update to C_21.1.0.8-r5\u003c/p\u003e\u003cp\u003eSP111: Update to 52.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e"
            }
          ],
          "value": "Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u00a0\n https://www.milesight.com/support/download/firmware \n\nMS-Cxx63-PD: Update to 51.7.0.77-r13\n\nMS-Cxx64-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx73-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx75-xxPD: Update to 51.7.0.77-r13\n\nMS-Cxx83-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx74-PA: Update to 3x.8.0.3-r13\n\nMS-C8477-HPG1: Update to 63.8.0.4-r4\n\n\u00a0MS-C8477-PC: Update to 48.8.0.4-r4\n\nMS-C5321-FPE: Update to 62.8.0.4-r6\n\nMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\n\nMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx76-PE: Update to 61.8.0.5-r2\n\nMS-Cxx65-PE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\n\nMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u00a0\n\nMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\n\nPMC8266-FPE: Update to PO_61.8.0.4-r1\n\nPMC8266-FGPE: Update to PO_61.8.0.4-r1\n\nPM3322-E: Update to PI_61.8.0.3-r5\n\nTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u00a0\n\nTS5366-X12RIPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS5510-GVH: Update to T_47.8.0.4-r8\n\nTS5510-GH: Update to T_47.8.0.4-r8\n\nTS5511-GVH: Update to T_47.8.0.4-r8\n\nTS2966-X12TPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RPE: Update to T_61.8.0.4-r4\n\nTS5366-X12PE: Update to T_61.8.0.4-r4\n\nTS8266-X4PE: Update to T_61.8.0.4-r4\n\nTS2966-X12TVPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RVPE: Update to T_61.8.0.4-r4\n\nTS5366-X12VPE: Update to T_61.8.0.4-r4\n\nTS8266-X4VPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RE: Update to T_61.8.0.4-r4\n\nTS4466-X4RWE: Update to T_61.8.0.4-r4\n\nTS8266-X4WE: Update to T_61.8.0.4-r4\n\nMS-C2964-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2972-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TVPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TGPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC/W: Update to T_45.8.0.3-r10\n\nTS2867-X5TPC: Update to T_45.8.0.3-r10\n\nTS2961-X12TPC: Update to T_45.8.0.3-r10\n\nTS8266-FPC/P: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\n\nMS-C5361-X12LPC: Update to T_45.8.0.3-r10\n\nMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\n\nSC211: Update to C_21.1.0.8-r5\n\nSP111: Update to 52.8.0.4-r6\n\nMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight asks all users to report potential security vulnerabilities to security@milesight.com.\u003cbr\u003e\u003ca href=\"mailto:security@milesight.com\"\u003emailto:security@milesight.com\u003c/a\u003e\u003cbr\u003eLearn more: Milesight Vulnerability Reporting Policy\u003cbr\u003e\u003ca href=\"https://www.milesight.com/legal/vulnerability-report\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/legal/vulnerability-report\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "Milesight asks all users to report potential security vulnerabilities to security@milesight.com.\n mailto:security@milesight.com \nLearn more: Milesight Vulnerability Reporting Policy\n https://www.milesight.com/legal/vulnerability-report"
        }
      ],
      "source": {
        "advisory": "ICSA-26-113-03",
        "discovery": "EXTERNAL"
      },
      "title": "Milesight Cameras Heap-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-20766",
    "datePublished": "2026-04-27T23:45:52.896Z",
    "dateReserved": "2026-03-12T17:51:09.860Z",
    "dateUpdated": "2026-04-28T14:39:17.799Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-32649 (GCVE-0-2026-32649)

Vulnerability from cvelistv5 – Published: 2026-04-27 23:42 – Updated: 2026-04-28 14:42
VLAI?
Title
Milesight Cameras OS Command Injection
Summary
A command injection vulnerability exists in the web server of specific firmware versions of Milesight cameras.
CWE
Assigner
Impacted products
Vendor Product Version
Milesight MS-Cxx63-PD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx64-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx73-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx75-xxPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx83-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx74-PA Affected: 0 , ≤ 3x.8.0.3-r11 (custom)
Create a notification for this product.
    Milesight MS-C8477-HPG1 Affected: 0 , ≤ 63.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C8477-PC Affected: 0 , ≤ 48.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C5321-FPE Affected: 0 , ≤ 62.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx52-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxGPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx61-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx67-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx71-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx41-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx76-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx65-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-CQxx31-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx68-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx72-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-NxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxC Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxG Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxH Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxT Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight PMC8266-FPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PMC8266-FGPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PM3322-E Affected: 0 , ≤ PI_61.8.0.3_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5510-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r7 (custom)
Create a notification for this product.
    Milesight TS5510-GH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS5511-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS2966-X12TPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS2966-X12TVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RWE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4WE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight MS-C2964-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2972-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-RFLWPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TGPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC/W Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2867-X5TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2961-X12TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS8266-FPC/P Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5361-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxxGOPC Affected: 0 , ≤ 45.8.0.2-AIoT-r4 (custom)
Create a notification for this product.
    Milesight SC211 Affected: 0 , ≤ C_21.1.0.8-r4 (custom)
Create a notification for this product.
    Milesight SP111 Affected: 0 , ≤ 52.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx66-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
Credits
Souvik Kandar reported these vulnerabilities to CISA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-32649",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-28T14:42:25.685037Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-28T14:42:37.926Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx63-PD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx64-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx73-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx75-xxPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx83-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx74-PA",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "3x.8.0.3-r11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-HPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-PC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "48.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5321-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "62.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx52-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx61-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx67-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx71-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx41-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx76-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx65-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx31-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx68-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-NxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxG",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxT",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PM3322-E",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PI_61.8.0.3_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5511-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RWE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4WE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2964-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2972-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-RFLWPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TGPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC/W",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2867-X5TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2961-X12TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-FPC/P",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5361-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxxGOPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "45.8.0.2-AIoT-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SC211",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "C_21.1.0.8-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SP111",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "52.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Souvik Kandar reported these vulnerabilities to CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan\u003eA command injection vulnerability exists in the web server of specific firmware versions of Milesight cameras.\u003c/span\u003e"
            }
          ],
          "value": "A command injection vulnerability exists in the web server of specific firmware versions of Milesight cameras."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-27T23:42:44.761Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-113-03.json"
        },
        {
          "url": "https://www.milesight.com/support/download/firmware"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u0026nbsp;\u003cbr\u003e\u003ca href=\"https://www.milesight.com/support/download/firmware\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/support/download/firmware\u003c/a\u003e\u003c/p\u003e\u003cp\u003eMS-Cxx63-PD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx64-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx73-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx75-xxPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx83-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx74-PA: Update to 3x.8.0.3-r13\u003c/p\u003e\u003cp\u003eMS-C8477-HPG1: Update to 63.8.0.4-r4\u003c/p\u003e\u003cp\u003e\u0026nbsp;MS-C8477-PC: Update to 48.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C5321-FPE: Update to 62.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx76-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx65-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u0026nbsp;\u003c/p\u003e\u003cp\u003eMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003ePMC8266-FPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePMC8266-FGPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePM3322-E: Update to PI_61.8.0.3-r5\u003c/p\u003e\u003cp\u003eTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u0026nbsp;\u003c/p\u003e\u003cp\u003eTS5366-X12RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5510-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5510-GH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5511-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS2966-X12TPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS2966-X12TVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RWE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4WE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C2964-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2972-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TGPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC/W: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2867-X5TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2961-X12TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS8266-FPC/P: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5361-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\u003c/p\u003e\u003cp\u003eSC211: Update to C_21.1.0.8-r5\u003c/p\u003e\u003cp\u003eSP111: Update to 52.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e"
            }
          ],
          "value": "Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u00a0\n https://www.milesight.com/support/download/firmware \n\nMS-Cxx63-PD: Update to 51.7.0.77-r13\n\nMS-Cxx64-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx73-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx75-xxPD: Update to 51.7.0.77-r13\n\nMS-Cxx83-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx74-PA: Update to 3x.8.0.3-r13\n\nMS-C8477-HPG1: Update to 63.8.0.4-r4\n\n\u00a0MS-C8477-PC: Update to 48.8.0.4-r4\n\nMS-C5321-FPE: Update to 62.8.0.4-r6\n\nMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\n\nMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx76-PE: Update to 61.8.0.5-r2\n\nMS-Cxx65-PE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\n\nMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u00a0\n\nMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\n\nPMC8266-FPE: Update to PO_61.8.0.4-r1\n\nPMC8266-FGPE: Update to PO_61.8.0.4-r1\n\nPM3322-E: Update to PI_61.8.0.3-r5\n\nTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u00a0\n\nTS5366-X12RIPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS5510-GVH: Update to T_47.8.0.4-r8\n\nTS5510-GH: Update to T_47.8.0.4-r8\n\nTS5511-GVH: Update to T_47.8.0.4-r8\n\nTS2966-X12TPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RPE: Update to T_61.8.0.4-r4\n\nTS5366-X12PE: Update to T_61.8.0.4-r4\n\nTS8266-X4PE: Update to T_61.8.0.4-r4\n\nTS2966-X12TVPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RVPE: Update to T_61.8.0.4-r4\n\nTS5366-X12VPE: Update to T_61.8.0.4-r4\n\nTS8266-X4VPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RE: Update to T_61.8.0.4-r4\n\nTS4466-X4RWE: Update to T_61.8.0.4-r4\n\nTS8266-X4WE: Update to T_61.8.0.4-r4\n\nMS-C2964-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2972-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TVPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TGPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC/W: Update to T_45.8.0.3-r10\n\nTS2867-X5TPC: Update to T_45.8.0.3-r10\n\nTS2961-X12TPC: Update to T_45.8.0.3-r10\n\nTS8266-FPC/P: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\n\nMS-C5361-X12LPC: Update to T_45.8.0.3-r10\n\nMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\n\nSC211: Update to C_21.1.0.8-r5\n\nSP111: Update to 52.8.0.4-r6\n\nMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight asks all users to report potential security vulnerabilities to security@milesight.com.\u003cbr\u003e\u003ca href=\"mailto:security@milesight.com\"\u003emailto:security@milesight.com\u003c/a\u003e\u003cbr\u003eLearn more: Milesight Vulnerability Reporting Policy\u003cbr\u003e\u003ca href=\"https://www.milesight.com/legal/vulnerability-report\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/legal/vulnerability-report\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "Milesight asks all users to report potential security vulnerabilities to security@milesight.com.\n mailto:security@milesight.com \nLearn more: Milesight Vulnerability Reporting Policy\n https://www.milesight.com/legal/vulnerability-report"
        }
      ],
      "source": {
        "advisory": "ICSA-26-113-03",
        "discovery": "EXTERNAL"
      },
      "title": "Milesight Cameras OS Command Injection",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-32649",
    "datePublished": "2026-04-27T23:42:44.761Z",
    "dateReserved": "2026-03-12T17:51:09.881Z",
    "dateUpdated": "2026-04-28T14:42:37.926Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-32644 (GCVE-0-2026-32644)

Vulnerability from cvelistv5 – Published: 2026-04-27 23:40 – Updated: 2026-04-28 14:45
VLAI?
Title
Milesight Cameras Use of Hard-coded Cryptographic Key
Summary
Specific firmware versions of Milesight AIOT cameras use SSL certificates with default private keys.
CWE
Assigner
Impacted products
Vendor Product Version
Milesight MS-Cxx63-PD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx64-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx73-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx75-xxPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx83-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx74-PA Affected: 0 , ≤ 3x.8.0.3-r11 (custom)
Create a notification for this product.
    Milesight MS-C8477-HPG1 Affected: 0 , ≤ 63.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C8477-PC Affected: 0 , ≤ 48.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C5321-FPE Affected: 0 , ≤ 62.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx52-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxGPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx61-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx67-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx71-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx41-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx76-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx65-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-CQxx31-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx68-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx72-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-NxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxC Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxG Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxH Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxT Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight PMC8266-FPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PMC8266-FGPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PM3322-E Affected: 0 , ≤ PI_61.8.0.3_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5510-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r7 (custom)
Create a notification for this product.
    Milesight TS5510-GH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS5511-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS2966-X12TPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS2966-X12TVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RWE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4WE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight MS-C2964-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2972-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-RFLWPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TGPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC/W Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2867-X5TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2961-X12TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS8266-FPC/P Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5361-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxxGOPC Affected: 0 , ≤ 45.8.0.2-AIoT-r4 (custom)
Create a notification for this product.
    Milesight SC211 Affected: 0 , ≤ C_21.1.0.8-r4 (custom)
Create a notification for this product.
    Milesight SP111 Affected: 0 , ≤ 52.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx66-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
Credits
Souvik Kandar reported these vulnerabilities to CISA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-32644",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-28T14:45:03.298830Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-28T14:45:19.107Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx63-PD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx64-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx73-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx75-xxPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx83-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx74-PA",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "3x.8.0.3-r11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-HPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-PC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "48.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5321-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "62.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx52-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx61-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx67-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx71-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx41-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx76-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx65-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx31-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx68-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-NxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxG",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxT",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PM3322-E",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PI_61.8.0.3_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5511-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RWE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4WE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2964-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2972-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-RFLWPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TGPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC/W",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2867-X5TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2961-X12TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-FPC/P",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5361-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxxGOPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "45.8.0.2-AIoT-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SC211",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "C_21.1.0.8-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SP111",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "52.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Souvik Kandar reported these vulnerabilities to CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan\u003eSpecific firmware versions of Milesight AIOT cameras use SSL certificates with default private keys.\u003c/span\u003e"
            }
          ],
          "value": "Specific firmware versions of Milesight AIOT cameras use SSL certificates with default private keys."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-27T23:40:25.181Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-113-03.json"
        },
        {
          "url": "https://www.milesight.com/support/download/firmware"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u0026nbsp;\u003cbr\u003e\u003ca href=\"https://www.milesight.com/support/download/firmware\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/support/download/firmware\u003c/a\u003e\u003c/p\u003e\u003cp\u003eMS-Cxx63-PD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx64-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx73-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx75-xxPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx83-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx74-PA: Update to 3x.8.0.3-r13\u003c/p\u003e\u003cp\u003eMS-C8477-HPG1: Update to 63.8.0.4-r4\u003c/p\u003e\u003cp\u003e\u0026nbsp;MS-C8477-PC: Update to 48.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C5321-FPE: Update to 62.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx76-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx65-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u0026nbsp;\u003c/p\u003e\u003cp\u003eMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003ePMC8266-FPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePMC8266-FGPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePM3322-E: Update to PI_61.8.0.3-r5\u003c/p\u003e\u003cp\u003eTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u0026nbsp;\u003c/p\u003e\u003cp\u003eTS5366-X12RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5510-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5510-GH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5511-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS2966-X12TPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS2966-X12TVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RWE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4WE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C2964-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2972-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TGPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC/W: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2867-X5TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2961-X12TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS8266-FPC/P: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5361-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\u003c/p\u003e\u003cp\u003eSC211: Update to C_21.1.0.8-r5\u003c/p\u003e\u003cp\u003eSP111: Update to 52.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e"
            }
          ],
          "value": "Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u00a0\n https://www.milesight.com/support/download/firmware \n\nMS-Cxx63-PD: Update to 51.7.0.77-r13\n\nMS-Cxx64-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx73-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx75-xxPD: Update to 51.7.0.77-r13\n\nMS-Cxx83-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx74-PA: Update to 3x.8.0.3-r13\n\nMS-C8477-HPG1: Update to 63.8.0.4-r4\n\n\u00a0MS-C8477-PC: Update to 48.8.0.4-r4\n\nMS-C5321-FPE: Update to 62.8.0.4-r6\n\nMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\n\nMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx76-PE: Update to 61.8.0.5-r2\n\nMS-Cxx65-PE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\n\nMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u00a0\n\nMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\n\nPMC8266-FPE: Update to PO_61.8.0.4-r1\n\nPMC8266-FGPE: Update to PO_61.8.0.4-r1\n\nPM3322-E: Update to PI_61.8.0.3-r5\n\nTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u00a0\n\nTS5366-X12RIPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS5510-GVH: Update to T_47.8.0.4-r8\n\nTS5510-GH: Update to T_47.8.0.4-r8\n\nTS5511-GVH: Update to T_47.8.0.4-r8\n\nTS2966-X12TPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RPE: Update to T_61.8.0.4-r4\n\nTS5366-X12PE: Update to T_61.8.0.4-r4\n\nTS8266-X4PE: Update to T_61.8.0.4-r4\n\nTS2966-X12TVPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RVPE: Update to T_61.8.0.4-r4\n\nTS5366-X12VPE: Update to T_61.8.0.4-r4\n\nTS8266-X4VPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RE: Update to T_61.8.0.4-r4\n\nTS4466-X4RWE: Update to T_61.8.0.4-r4\n\nTS8266-X4WE: Update to T_61.8.0.4-r4\n\nMS-C2964-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2972-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TVPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TGPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC/W: Update to T_45.8.0.3-r10\n\nTS2867-X5TPC: Update to T_45.8.0.3-r10\n\nTS2961-X12TPC: Update to T_45.8.0.3-r10\n\nTS8266-FPC/P: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\n\nMS-C5361-X12LPC: Update to T_45.8.0.3-r10\n\nMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\n\nSC211: Update to C_21.1.0.8-r5\n\nSP111: Update to 52.8.0.4-r6\n\nMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight asks all users to report potential security vulnerabilities to security@milesight.com.\u003cbr\u003e\u003ca href=\"mailto:security@milesight.com\"\u003emailto:security@milesight.com\u003c/a\u003e\u003cbr\u003eLearn more: Milesight Vulnerability Reporting Policy\u003cbr\u003e\u003ca href=\"https://www.milesight.com/legal/vulnerability-report\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/legal/vulnerability-report\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "Milesight asks all users to report potential security vulnerabilities to security@milesight.com.\n mailto:security@milesight.com \nLearn more: Milesight Vulnerability Reporting Policy\n https://www.milesight.com/legal/vulnerability-report"
        }
      ],
      "source": {
        "advisory": "ICSA-26-113-03",
        "discovery": "EXTERNAL"
      },
      "title": "Milesight Cameras Use of Hard-coded Cryptographic Key",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-32644",
    "datePublished": "2026-04-27T23:40:25.181Z",
    "dateReserved": "2026-03-12T17:51:09.896Z",
    "dateUpdated": "2026-04-28T14:45:19.107Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-27785 (GCVE-0-2026-27785)

Vulnerability from cvelistv5 – Published: 2026-04-27 23:38 – Updated: 2026-04-28 12:40
VLAI?
Title
Milesight Cameras Use of Hard-coded Credentials
Summary
Specific firmware versions of Milesight AIOT camera firmware contain hard-coded credentials.
CWE
Assigner
Impacted products
Vendor Product Version
Milesight MS-Cxx63-PD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx64-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx73-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx75-xxPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx83-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx74-PA Affected: 0 , ≤ 3x.8.0.3-r11 (custom)
Create a notification for this product.
    Milesight MS-C8477-HPG1 Affected: 0 , ≤ 63.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C8477-PC Affected: 0 , ≤ 48.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C5321-FPE Affected: 0 , ≤ 62.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx52-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxGPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx61-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx67-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx71-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx41-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx76-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx65-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-CQxx31-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx68-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx72-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-NxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxC Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxG Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxH Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxT Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight PMC8266-FPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PMC8266-FGPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PM3322-E Affected: 0 , ≤ PI_61.8.0.3_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5510-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r7 (custom)
Create a notification for this product.
    Milesight TS5510-GH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS5511-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS2966-X12TPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS2966-X12TVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RWE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4WE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight MS-C2964-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2972-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-RFLWPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TGPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC/W Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2867-X5TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2961-X12TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS8266-FPC/P Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5361-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxxGOPC Affected: 0 , ≤ 45.8.0.2-AIoT-r4 (custom)
Create a notification for this product.
    Milesight SC211 Affected: 0 , ≤ C_21.1.0.8-r4 (custom)
Create a notification for this product.
    Milesight SP111 Affected: 0 , ≤ 52.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx66-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
Credits
Souvik Kandar reported these vulnerabilities to CISA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-27785",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-28T12:40:31.458437Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-28T12:40:37.832Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx63-PD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx64-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx73-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx75-xxPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx83-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx74-PA",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "3x.8.0.3-r11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-HPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-PC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "48.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5321-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "62.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx52-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx61-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx67-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx71-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx41-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx76-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx65-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx31-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx68-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-NxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxG",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxT",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PM3322-E",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PI_61.8.0.3_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5511-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RWE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4WE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2964-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2972-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-RFLWPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TGPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC/W",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2867-X5TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2961-X12TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-FPC/P",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5361-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxxGOPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "45.8.0.2-AIoT-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SC211",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "C_21.1.0.8-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SP111",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "52.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Souvik Kandar reported these vulnerabilities to CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan\u003eSpecific firmware versions of Milesight AIOT camera firmware contain hard-coded credentials.\u003c/span\u003e"
            }
          ],
          "value": "Specific firmware versions of Milesight AIOT camera firmware contain hard-coded credentials."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-27T23:38:10.844Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-113-03.json"
        },
        {
          "url": "https://www.milesight.com/support/download/firmware"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u0026nbsp;\u003cbr\u003e\u003ca href=\"https://www.milesight.com/support/download/firmware\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/support/download/firmware\u003c/a\u003e\u003c/p\u003e\u003cp\u003eMS-Cxx63-PD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx64-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx73-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx75-xxPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx83-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx74-PA: Update to 3x.8.0.3-r13\u003c/p\u003e\u003cp\u003eMS-C8477-HPG1: Update to 63.8.0.4-r4\u003c/p\u003e\u003cp\u003e\u0026nbsp;MS-C8477-PC: Update to 48.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C5321-FPE: Update to 62.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx76-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx65-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u0026nbsp;\u003c/p\u003e\u003cp\u003eMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003ePMC8266-FPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePMC8266-FGPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePM3322-E: Update to PI_61.8.0.3-r5\u003c/p\u003e\u003cp\u003eTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u0026nbsp;\u003c/p\u003e\u003cp\u003eTS5366-X12RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5510-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5510-GH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5511-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS2966-X12TPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS2966-X12TVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RWE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4WE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C2964-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2972-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TGPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC/W: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2867-X5TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2961-X12TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS8266-FPC/P: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5361-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\u003c/p\u003e\u003cp\u003eSC211: Update to C_21.1.0.8-r5\u003c/p\u003e\u003cp\u003eSP111: Update to 52.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e"
            }
          ],
          "value": "Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u00a0\n https://www.milesight.com/support/download/firmware \n\nMS-Cxx63-PD: Update to 51.7.0.77-r13\n\nMS-Cxx64-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx73-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx75-xxPD: Update to 51.7.0.77-r13\n\nMS-Cxx83-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx74-PA: Update to 3x.8.0.3-r13\n\nMS-C8477-HPG1: Update to 63.8.0.4-r4\n\n\u00a0MS-C8477-PC: Update to 48.8.0.4-r4\n\nMS-C5321-FPE: Update to 62.8.0.4-r6\n\nMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\n\nMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx76-PE: Update to 61.8.0.5-r2\n\nMS-Cxx65-PE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\n\nMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u00a0\n\nMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\n\nPMC8266-FPE: Update to PO_61.8.0.4-r1\n\nPMC8266-FGPE: Update to PO_61.8.0.4-r1\n\nPM3322-E: Update to PI_61.8.0.3-r5\n\nTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u00a0\n\nTS5366-X12RIPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS5510-GVH: Update to T_47.8.0.4-r8\n\nTS5510-GH: Update to T_47.8.0.4-r8\n\nTS5511-GVH: Update to T_47.8.0.4-r8\n\nTS2966-X12TPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RPE: Update to T_61.8.0.4-r4\n\nTS5366-X12PE: Update to T_61.8.0.4-r4\n\nTS8266-X4PE: Update to T_61.8.0.4-r4\n\nTS2966-X12TVPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RVPE: Update to T_61.8.0.4-r4\n\nTS5366-X12VPE: Update to T_61.8.0.4-r4\n\nTS8266-X4VPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RE: Update to T_61.8.0.4-r4\n\nTS4466-X4RWE: Update to T_61.8.0.4-r4\n\nTS8266-X4WE: Update to T_61.8.0.4-r4\n\nMS-C2964-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2972-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TVPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TGPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC/W: Update to T_45.8.0.3-r10\n\nTS2867-X5TPC: Update to T_45.8.0.3-r10\n\nTS2961-X12TPC: Update to T_45.8.0.3-r10\n\nTS8266-FPC/P: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\n\nMS-C5361-X12LPC: Update to T_45.8.0.3-r10\n\nMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\n\nSC211: Update to C_21.1.0.8-r5\n\nSP111: Update to 52.8.0.4-r6\n\nMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight asks all users to report potential security vulnerabilities to security@milesight.com.\u003cbr\u003e\u003ca href=\"mailto:security@milesight.com\"\u003emailto:security@milesight.com\u003c/a\u003e\u003cbr\u003eLearn more: Milesight Vulnerability Reporting Policy\u003cbr\u003e\u003ca href=\"https://www.milesight.com/legal/vulnerability-report\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/legal/vulnerability-report\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "Milesight asks all users to report potential security vulnerabilities to security@milesight.com.\n mailto:security@milesight.com \nLearn more: Milesight Vulnerability Reporting Policy\n https://www.milesight.com/legal/vulnerability-report"
        }
      ],
      "source": {
        "advisory": "ICSA-26-113-03",
        "discovery": "EXTERNAL"
      },
      "title": "Milesight Cameras Use of Hard-coded Credentials",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-27785",
    "datePublished": "2026-04-27T23:38:10.844Z",
    "dateReserved": "2026-03-12T17:51:09.903Z",
    "dateUpdated": "2026-04-28T12:40:37.832Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-28747 (GCVE-0-2026-28747)

Vulnerability from cvelistv5 – Published: 2026-04-27 22:44 – Updated: 2026-04-28 14:35
VLAI?
Title
Milesight Cameras Authorization Bypass Through User-Controlled Key
Summary
A weak key generation vulnerability exists in specific firmware versions of Milesight AIOT cameras allows authorization to be bypassed.
CWE
Assigner
Impacted products
Vendor Product Version
Milesight MS-Cxx63-PD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx64-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx73-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx75-xxPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx83-xPD Affected: 0 , ≤ 51.7.0.77-r12 (custom)
Create a notification for this product.
    Milesight MS-Cxx74-PA Affected: 0 , ≤ 3x.8.0.3-r11 (custom)
Create a notification for this product.
    Milesight MS-C8477-HPG1 Affected: 0 , ≤ 63.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C8477-PC Affected: 0 , ≤ 48.8.0.4-r3 (custom)
Create a notification for this product.
    Milesight MS-C5321-FPE Affected: 0 , ≤ 62.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx52-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxGPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx61-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx67-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx71-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx41-xxxPE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx76-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx65-PE Affected: 0 , ≤ 61.8.0.5-r2 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx62-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-Cxx72-xxxG1 Affected: 0 , ≤ 63.8.0.5-r3 (custom)
Create a notification for this product.
    Milesight MS-CQxx31-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx68-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-CQxx72-xxxG1 Affected: 0 , ≤ CQ_63.8.0.5-r1 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-NxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxC Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxE Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxG Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxH Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight MS-Nxxxx-xxT Affected: 0 , ≤ 7x.9.0.19-r5 (custom)
Create a notification for this product.
    Milesight PMC8266-FPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PMC8266-FGPE Affected: 0 , ≤ PO_61.8.0.4_LPR (custom)
Create a notification for this product.
    Milesight PM3322-E Affected: 0 , ≤ PI_61.8.0.3_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-RFIVPG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4RIWG1 Affected: 0 , ≤ T_63.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5510-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r7 (custom)
Create a notification for this product.
    Milesight TS5510-GH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS5511-GVH Affected: 0 , ≤ T_47.8.0.4_LPR-r6 (custom)
Create a notification for this product.
    Milesight TS2966-X12TPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4PE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS2966-X12TVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RVPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS5366-X12VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4VPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RPE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4441-X36RE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS4466-X4RWE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight TS8266-X4WE Affected: 0 , ≤ T_61.8.0.4_LPR-r3 (custom)
Create a notification for this product.
    Milesight MS-C2964-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2972-RFLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-RFLWPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2866-X4TGPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2841-X36TPC/W Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2867-X5TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS2961-X12TPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight TS8266-FPC/P Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C2966-X12RLVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5366-X12LVPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-C5361-X12LPC Affected: 0 , ≤ T_45.8.0.3-r9 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-xxxxGOPC Affected: 0 , ≤ 45.8.0.2-AIoT-r4 (custom)
Create a notification for this product.
    Milesight SC211 Affected: 0 , ≤ C_21.1.0.8-r4 (custom)
Create a notification for this product.
    Milesight SP111 Affected: 0 , ≤ 52.8.0.4-r5 (custom)
Create a notification for this product.
    Milesight MS-Cxx66-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-RFIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx66-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
    Milesight MS-Cxx72-FIPKG1 Affected: 0 , ≤ 63.8.0.4-r1-NX (custom)
Create a notification for this product.
Credits
Souvik Kandar reported these vulnerabilities to CISA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-28747",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-28T13:40:48.550832Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-28T14:35:33.191Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx63-PD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx64-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx73-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx75-xxPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx83-xPD",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "51.7.0.77-r12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx74-PA",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "3x.8.0.3-r11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-HPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C8477-PC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "48.8.0.4-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5321-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "62.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx52-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx61-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx67-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx71-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx41-xxxPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx76-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx65-PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "61.8.0.5-r2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx62-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.5-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx31-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx68-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-CQxx72-xxxG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "CQ_63.8.0.5-r1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-NxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxG",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Nxxxx-xxT",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "7x.9.0.19-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PMC8266-FGPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PO_61.8.0.4_LPR",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PM3322-E",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "PI_61.8.0.3_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-RFIVPG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4RIWG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_63.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5510-GH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5511-GVH",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_47.8.0.4_LPR-r6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4PE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2966-X12TVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RVPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS5366-X12VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4VPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RPE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4441-X36RE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS4466-X4RWE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-X4WE",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_61.8.0.4_LPR-r3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2964-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2972-RFLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-RFLWPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2866-X4TGPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2841-X36TPC/W",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2867-X5TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS2961-X12TPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TS8266-FPC/P",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C2966-X12RLVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5366-X12LVPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-C5361-X12LPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "T_45.8.0.3-r9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-xxxxGOPC",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "45.8.0.2-AIoT-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SC211",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "C_21.1.0.8-r4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SP111",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "52.8.0.4-r5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-RFIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx66-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MS-Cxx72-FIPKG1",
          "vendor": "Milesight",
          "versions": [
            {
              "lessThanOrEqual": "63.8.0.4-r1-NX",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Souvik Kandar reported these vulnerabilities to CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A weak key generation vulnerability exists in specific firmware versions of Milesight AIOT cameras allows authorization to be bypassed.\u0026nbsp;"
            }
          ],
          "value": "A weak key generation vulnerability exists in specific firmware versions of Milesight AIOT cameras allows authorization to be bypassed."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-27T23:31:53.318Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-113-03.json"
        },
        {
          "url": "https://www.milesight.com/support/download/firmware"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u0026nbsp;\u003cbr\u003e\u003ca href=\"https://www.milesight.com/support/download/firmware\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/support/download/firmware\u003c/a\u003e\u003c/p\u003e\u003cp\u003eMS-Cxx63-PD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx64-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx73-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx75-xxPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx83-xPD: Update to 51.7.0.77-r13\u003c/p\u003e\u003cp\u003eMS-Cxx74-PA: Update to 3x.8.0.3-r13\u003c/p\u003e\u003cp\u003eMS-C8477-HPG1: Update to 63.8.0.4-r4\u003c/p\u003e\u003cp\u003e\u0026nbsp;MS-C8477-PC: Update to 48.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C5321-FPE: Update to 62.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx76-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx65-PE: Update to 61.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\u003c/p\u003e\u003cp\u003eMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u0026nbsp;\u003c/p\u003e\u003cp\u003eMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\u003c/p\u003e\u003cp\u003eMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003eMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\u003c/p\u003e\u003cp\u003ePMC8266-FPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePMC8266-FGPE: Update to PO_61.8.0.4-r1\u003c/p\u003e\u003cp\u003ePM3322-E: Update to PI_61.8.0.3-r5\u003c/p\u003e\u003cp\u003eTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u0026nbsp;\u003c/p\u003e\u003cp\u003eTS5366-X12RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-RFIVPG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4RIWG1: Update to T_63.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5510-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5510-GH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS5511-GVH: Update to T_47.8.0.4-r8\u003c/p\u003e\u003cp\u003eTS2966-X12TPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4PE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS2966-X12TVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RVPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS5366-X12VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4VPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RPE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4441-X36RE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS4466-X4RWE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eTS8266-X4WE: Update to T_61.8.0.4-r4\u003c/p\u003e\u003cp\u003eMS-C2964-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2972-RFLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2866-X4TGPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2841-X36TPC/W: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2867-X5TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS2961-X12TPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eTS8266-FPC/P: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-C5361-X12LPC: Update to T_45.8.0.3-r10\u003c/p\u003e\u003cp\u003eMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\u003c/p\u003e\u003cp\u003eSC211: Update to C_21.1.0.8-r5\u003c/p\u003e\u003cp\u003eSP111: Update to 52.8.0.4-r6\u003c/p\u003e\u003cp\u003eMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e\u003cp\u003eMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX\u003c/p\u003e"
            }
          ],
          "value": "Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware.\u00a0\n https://www.milesight.com/support/download/firmware \n\nMS-Cxx63-PD: Update to 51.7.0.77-r13\n\nMS-Cxx64-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx73-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx75-xxPD: Update to 51.7.0.77-r13\n\nMS-Cxx83-xPD: Update to 51.7.0.77-r13\n\nMS-Cxx74-PA: Update to 3x.8.0.3-r13\n\nMS-C8477-HPG1: Update to 63.8.0.4-r4\n\n\u00a0MS-C8477-PC: Update to 48.8.0.4-r4\n\nMS-C5321-FPE: Update to 62.8.0.4-r6\n\nMS-Cxx72-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx62-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx52-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxGPE: Update to 61.8.0.5-r2\n\nMS-Cxx61-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx67-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx71-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx41-xxxPE: Update to 61.8.0.5-r2\n\nMS-Cxx76-PE: Update to 61.8.0.5-r2\n\nMS-Cxx65-PE: Update to 61.8.0.5-r2\n\nMS-Cxx66-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx62-xxxG1: Update to 63.8.0.5-r4\n\nMS-Cxx72-xxxG1: Update to 63.8.0.5-r4\n\nMS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2\u00a0\n\nMS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2\n\nMS-Nxxxx-NxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxC: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxE: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxG: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxH: Update to 7x.9.0.19-r6\n\nMS-Nxxxx-xxT: Update to 7x.9.0.19-r6\n\nPMC8266-FPE: Update to PO_61.8.0.4-r1\n\nPMC8266-FGPE: Update to PO_61.8.0.4-r1\n\nPM3322-E: Update to PI_61.8.0.3-r5\n\nTS4466-X4RIPG1: Update to T_63.8.0.4-r4\u00a0\n\nTS5366-X12RIPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIVPG1: Update to T_63.8.0.4-r4\n\nTS8266-RFIVPG1: Update to T_63.8.0.4-r4\n\nTS4466-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS8266-X4RIWG1: Update to T_63.8.0.4-r4\n\nTS5510-GVH: Update to T_47.8.0.4-r8\n\nTS5510-GH: Update to T_47.8.0.4-r8\n\nTS5511-GVH: Update to T_47.8.0.4-r8\n\nTS2966-X12TPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RPE: Update to T_61.8.0.4-r4\n\nTS5366-X12PE: Update to T_61.8.0.4-r4\n\nTS8266-X4PE: Update to T_61.8.0.4-r4\n\nTS2966-X12TVPE: Update to T_61.8.0.4-r4\n\nTS4466-X4RVPE: Update to T_61.8.0.4-r4\n\nTS5366-X12VPE: Update to T_61.8.0.4-r4\n\nTS8266-X4VPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RPE: Update to T_61.8.0.4-r4\n\nTS4441-X36RE: Update to T_61.8.0.4-r4\n\nTS4466-X4RWE: Update to T_61.8.0.4-r4\n\nTS8266-X4WE: Update to T_61.8.0.4-r4\n\nMS-C2964-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2972-RFLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-RFLWPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TVPC: Update to T_45.8.0.3-r10\n\nTS2866-X4TGPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC: Update to T_45.8.0.3-r10\n\nTS2841-X36TPC/W: Update to T_45.8.0.3-r10\n\nTS2867-X5TPC: Update to T_45.8.0.3-r10\n\nTS2961-X12TPC: Update to T_45.8.0.3-r10\n\nTS8266-FPC/P: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLPC: Update to T_45.8.0.3-r10\n\nMS-C2966-X12RLVPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LPC: Update to T_45.8.0.3-r10\n\nMS-C5366-X12LVPC: Update to T_45.8.0.3-r10\n\nMS-C5361-X12LPC: Update to T_45.8.0.3-r10\n\nMS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5\n\nSC211: Update to C_21.1.0.8-r5\n\nSP111: Update to 52.8.0.4-r6\n\nMS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX\n\nMS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMilesight asks all users to report potential security vulnerabilities to security@milesight.com.\u003cbr\u003e\u003ca href=\"mailto:security@milesight.com\"\u003emailto:security@milesight.com\u003c/a\u003e\u003cbr\u003eLearn more: Milesight Vulnerability Reporting Policy\u003cbr\u003e\u003ca href=\"https://www.milesight.com/legal/vulnerability-report\" title=\"(opens in a new window)\"\u003ehttps://www.milesight.com/legal/vulnerability-report\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "Milesight asks all users to report potential security vulnerabilities to security@milesight.com.\n mailto:security@milesight.com \nLearn more: Milesight Vulnerability Reporting Policy\n https://www.milesight.com/legal/vulnerability-report"
        }
      ],
      "source": {
        "advisory": "ICSA-26-113-03",
        "discovery": "EXTERNAL"
      },
      "title": "Milesight Cameras Authorization Bypass Through User-Controlled Key",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-28747",
    "datePublished": "2026-04-27T22:44:52.012Z",
    "dateReserved": "2026-03-12T17:51:09.913Z",
    "dateUpdated": "2026-04-28T14:35:33.191Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-25775 (GCVE-0-2026-25775)

Vulnerability from cvelistv5 – Published: 2026-04-24 00:06 – Updated: 2026-04-24 12:16
VLAI?
Title
SenseLive X3050 Missing authentication for critical function
Summary
A vulnerability in SenseLive X3050’s remote management service allows firmware retrieval and update operations to be performed without authentication or authorization. The service accepts firmware-related requests from any reachable host and does not verify user privileges, integrity of uploaded images, or the authenticity of provided firmware.
CWE
  • CWE-306 - Missing authentication for critical function
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-25775",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T12:16:12.459353Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T12:16:24.207Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in\u0026nbsp;SenseLive\u0026nbsp;X3050\u2019s remote management service allows firmware retrieval and update operations to be performed without authentication or authorization. The service accepts firmware-related requests from any reachable host and does not verify user privileges, integrity of uploaded images, or the authenticity of provided firmware."
            }
          ],
          "value": "A vulnerability in\u00a0SenseLive\u00a0X3050\u2019s remote management service allows firmware retrieval and update operations to be performed without authentication or authorization. The service accepts firmware-related requests from any reachable host and does not verify user privileges, integrity of uploaded images, or the authenticity of provided firmware."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing authentication for critical function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-24T00:06:16.965Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Missing authentication for critical function",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-25775",
    "datePublished": "2026-04-24T00:06:16.965Z",
    "dateReserved": "2026-04-14T15:57:15.003Z",
    "dateUpdated": "2026-04-24T12:16:24.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-35064 (GCVE-0-2026-35064)

Vulnerability from cvelistv5 – Published: 2026-04-24 00:04 – Updated: 2026-04-24 13:09
VLAI?
Title
SenseLive X3050 Missing authentication for critical function
Summary
A vulnerability in SenseLive X3050’s management ecosystem allows unauthenticated discovery of deployed units through the vendor’s management protocol, enabling identification of device presence, identifiers, and management interfaces without requiring credentials. Because discovery functions are exposed by the underlying service rather than gated by authentication, an attacker on the same network segment can rapidly enumerate targeted devices.
CWE
  • CWE-306 - Missing authentication for critical function
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-35064",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T13:09:03.510590Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T13:09:10.289Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in\u0026nbsp;SenseLive\u0026nbsp;X3050\u2019s management ecosystem allows unauthenticated discovery of deployed units through the vendor\u2019s management protocol, enabling identification of device presence, identifiers, and management interfaces without requiring credentials. Because discovery functions are exposed by the underlying service rather than gated by authentication, an attacker on the same network segment can rapidly enumerate targeted devices."
            }
          ],
          "value": "A vulnerability in\u00a0SenseLive\u00a0X3050\u2019s management ecosystem allows unauthenticated discovery of deployed units through the vendor\u2019s management protocol, enabling identification of device presence, identifiers, and management interfaces without requiring credentials. Because discovery functions are exposed by the underlying service rather than gated by authentication, an attacker on the same network segment can rapidly enumerate targeted devices."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing authentication for critical function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-24T00:04:30.693Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Missing authentication for critical function",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-35064",
    "datePublished": "2026-04-24T00:04:30.693Z",
    "dateReserved": "2026-04-14T15:57:14.994Z",
    "dateUpdated": "2026-04-24T13:09:10.289Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-40620 (GCVE-0-2026-40620)

Vulnerability from cvelistv5 – Published: 2026-04-24 00:02 – Updated: 2026-04-24 13:09
VLAI?
Title
SenseLive X3050 Missing authentication for critical function
Summary
A vulnerability in SenseLive X3050’s embedded management service allows full administrative control to be established without any form of authentication or authorization on the SenseLive config application. The service accepts management connections from any reachable host, enabling unrestricted modification of critical configuration parameters, operational modes, and device state through a vendor-supplied or compatible client.
CWE
  • CWE-306 - Missing authentication for critical function
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-40620",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T13:09:30.566885Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T13:09:37.232Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in\u0026nbsp;SenseLive\u0026nbsp;X3050\u2019s embedded management service allows full administrative control to be established without any form of authentication or authorization on the SenseLive config application. The service accepts management connections from any reachable host, enabling unrestricted modification of critical configuration parameters, operational modes, and device state through a vendor-supplied or compatible client."
            }
          ],
          "value": "A vulnerability in\u00a0SenseLive\u00a0X3050\u2019s embedded management service allows full administrative control to be established without any form of authentication or authorization on the SenseLive config application. The service accepts management connections from any reachable host, enabling unrestricted modification of critical configuration parameters, operational modes, and device state through a vendor-supplied or compatible client."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing authentication for critical function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-24T00:02:57.571Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Missing authentication for critical function",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-40620",
    "datePublished": "2026-04-24T00:02:57.571Z",
    "dateReserved": "2026-04-14T15:57:14.990Z",
    "dateUpdated": "2026-04-24T13:09:37.232Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-27841 (GCVE-0-2026-27841)

Vulnerability from cvelistv5 – Published: 2026-04-24 00:00 – Updated: 2026-04-24 18:18
VLAI?
Title
SenseLive X3050 Cross-Site request forgery
Summary
A vulnerability in SenseLive X3050's web management interface allows state-changing operations to be triggered without proper Cross-Site Request Forgery (CSRF) protections. Because the application does not enforce server-side validation of request origin or implement CSRF tokens, a malicious external webpage could cause a user's browser to submit unauthorized configuration requests to the device.
CWE
  • CWE-352 - Cross-Site request forgery (CSRF)
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-27841",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T16:49:45.649408Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T18:18:30.759Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in\u0026nbsp;SenseLive\u0026nbsp;X3050\u0027s web management interface allows state-changing operations to be triggered without proper Cross-Site Request Forgery (CSRF) protections. Because the application does not enforce server-side validation of request origin or implement CSRF tokens, a malicious external webpage could cause a user\u0027s browser to submit unauthorized configuration requests to the device."
            }
          ],
          "value": "A vulnerability in\u00a0SenseLive\u00a0X3050\u0027s web management interface allows state-changing operations to be triggered without proper Cross-Site Request Forgery (CSRF) protections. Because the application does not enforce server-side validation of request origin or implement CSRF tokens, a malicious external webpage could cause a user\u0027s browser to submit unauthorized configuration requests to the device."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352 Cross-Site request forgery (CSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-24T00:00:57.349Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Cross-Site request forgery",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-27841",
    "datePublished": "2026-04-24T00:00:57.349Z",
    "dateReserved": "2026-04-14T15:57:14.980Z",
    "dateUpdated": "2026-04-24T18:18:30.759Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-40623 (GCVE-0-2026-40623)

Vulnerability from cvelistv5 – Published: 2026-04-23 23:58 – Updated: 2026-04-24 18:18
VLAI?
Title
SenseLive X3050 Missing Authorization
Summary
A vulnerability in SenseLive X3050's web management interface allows critical system and network configuration parameters to be modified without sufficient validation and safety controls. Due to inadequate enforcement of constraints on sensitive functions, parameters such as IP addressing, watchdog timers, reconnect intervals, and service ports can be set to unsupported or unsafe values. These configuration changes directly affect core device behaviour and recovery mechanisms. The lack of proper validation and safeguards allows critical system functions to be altered in a manner that can destabilize device operation or render the device persistently unavailable.
CWE
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-40623",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T17:05:39.233646Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T18:18:37.202Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in\u0026nbsp;SenseLive\u0026nbsp;X3050\u0027s web management interface allows critical system and network configuration parameters to be modified without sufficient validation and safety controls. Due to inadequate enforcement of constraints on sensitive functions, parameters such as IP addressing, watchdog timers, reconnect intervals, and service ports can be set to unsupported or unsafe values. These configuration changes directly affect core device behaviour and recovery mechanisms. The lack of proper validation and safeguards allows critical system functions to be altered in a manner that can destabilize device operation or render the device persistently unavailable."
            }
          ],
          "value": "A vulnerability in\u00a0SenseLive\u00a0X3050\u0027s web management interface allows critical system and network configuration parameters to be modified without sufficient validation and safety controls. Due to inadequate enforcement of constraints on sensitive functions, parameters such as IP addressing, watchdog timers, reconnect intervals, and service ports can be set to unsupported or unsafe values. These configuration changes directly affect core device behaviour and recovery mechanisms. The lack of proper validation and safeguards allows critical system functions to be altered in a manner that can destabilize device operation or render the device persistently unavailable."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862 Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T23:58:47.343Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Missing Authorization",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-40623",
    "datePublished": "2026-04-23T23:58:47.343Z",
    "dateReserved": "2026-04-14T15:57:14.970Z",
    "dateUpdated": "2026-04-24T18:18:37.202Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-40431 (GCVE-0-2026-40431)

Vulnerability from cvelistv5 – Published: 2026-04-23 23:56 – Updated: 2026-04-24 18:18
VLAI?
Title
SenseLive X3050 Cleartext transmission of sensitive information
Summary
A vulnerability exists in SenseLive X3050’s web management interface due to its reliance on unencrypted HTTP for all administrative communication. Because management traffic, including authentication attempts and configuration data, is transmitted in cleartext, an attacker with access to the same network segment could intercept or observe sensitive operational information.
CWE
  • CWE-319 - Cleartext transmission of sensitive information
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-40431",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T16:49:38.101024Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T18:18:43.495Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability exists in\u0026nbsp;SenseLive\u0026nbsp;X3050\u2019s web management interface due to its reliance on unencrypted HTTP for all administrative communication. Because management traffic, including authentication attempts and configuration data, is transmitted in cleartext, an attacker with access to the same network segment could intercept or observe sensitive operational information."
            }
          ],
          "value": "A vulnerability exists in\u00a0SenseLive\u00a0X3050\u2019s web management interface due to its reliance on unencrypted HTTP for all administrative communication. Because management traffic, including authentication attempts and configuration data, is transmitted in cleartext, an attacker with access to the same network segment could intercept or observe sensitive operational information."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext transmission of sensitive information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T23:56:49.967Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Cleartext transmission of sensitive information",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-40431",
    "datePublished": "2026-04-23T23:56:49.967Z",
    "dateReserved": "2026-04-14T15:57:14.948Z",
    "dateUpdated": "2026-04-24T18:18:43.495Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-27843 (GCVE-0-2026-27843)

Vulnerability from cvelistv5 – Published: 2026-04-23 23:54 – Updated: 2026-04-24 13:10
VLAI?
Title
SenseLive X3050 Missing authentication for critical function
Summary
A vulnerability exists in SenseLive X3050's web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems.
CWE
  • CWE-306 - Missing authentication for critical function
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-27843",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T13:10:32.973864Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T13:10:40.862Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability exists in\u0026nbsp;SenseLive X3050\u0027s web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems."
            }
          ],
          "value": "A vulnerability exists in\u00a0SenseLive X3050\u0027s web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing authentication for critical function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T23:54:55.051Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Missing authentication for critical function",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-27843",
    "datePublished": "2026-04-23T23:54:55.051Z",
    "dateReserved": "2026-04-14T16:05:54.167Z",
    "dateUpdated": "2026-04-24T13:10:40.862Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-39462 (GCVE-0-2026-39462)

Vulnerability from cvelistv5 – Published: 2026-04-23 23:52 – Updated: 2026-04-24 18:18
VLAI?
Title
SenseLive X3050 Insufficiently Protected Credentials
Summary
A vulnerability exists in SenseLive X3050’s web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly.
CWE
  • CWE-522 - Insufficiently Protected Credentials
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-39462",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T16:48:32.907201Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T18:18:50.532Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability exists in\u0026nbsp;SenseLive X3050\u2019s web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly."
            }
          ],
          "value": "A vulnerability exists in\u00a0SenseLive X3050\u2019s web management interface in which password updates are not reliably applied due to improper handling of credential changes on the backend. After the device undergoes a factory restore using the SenseLive Config 2.0 tool, the interface may indicate that the password update was successful; however, the system may continue to accept the previous or default credentials, demonstrating that the password-change process is not consistently enforced. Even after a factory reset, attempted password changes may fail to propagate correctly."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "CWE-522 Insufficiently Protected Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T23:52:16.129Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Insufficiently Protected Credentials",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-39462",
    "datePublished": "2026-04-23T23:52:16.129Z",
    "dateReserved": "2026-04-14T16:05:54.161Z",
    "dateUpdated": "2026-04-24T18:18:50.532Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-35503 (GCVE-0-2026-35503)

Vulnerability from cvelistv5 – Published: 2026-04-23 23:50 – Updated: 2026-04-24 13:51
VLAI?
Title
SenseLive X3050 Use of Hard-coded Credentials
Summary
A vulnerability in SenseLive X3050’s web management interface allows authentication logic to be performed entirely on the client side, relying on hardcoded values within browser-executed scripts rather than server-side verification. An attacker with access to the login page could retrieve these exposed parameters and gain unauthorized access to administrative functionality.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-35503",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T13:51:31.188310Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T13:51:40.131Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in\u0026nbsp;SenseLive X3050\u2019s web management interface allows authentication logic to be performed entirely on the client side, relying on hardcoded values within browser-executed scripts rather than server-side verification. An attacker with access to the login page could retrieve these exposed parameters and gain unauthorized access to administrative functionality."
            }
          ],
          "value": "A vulnerability in\u00a0SenseLive X3050\u2019s web management interface allows authentication logic to be performed entirely on the client side, relying on hardcoded values within browser-executed scripts rather than server-side verification. An attacker with access to the login page could retrieve these exposed parameters and gain unauthorized access to administrative functionality."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T23:50:03.513Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Use of Hard-coded Credentials",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-35503",
    "datePublished": "2026-04-23T23:50:03.513Z",
    "dateReserved": "2026-04-14T16:05:54.153Z",
    "dateUpdated": "2026-04-24T13:51:40.131Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-25720 (GCVE-0-2026-25720)

Vulnerability from cvelistv5 – Published: 2026-04-23 23:48 – Updated: 2026-04-24 13:11
VLAI?
Title
SenseLive X3050 Insufficient session expiration
Summary
A vulnerability exists in SenseLive X3050’s web management interface due to improper session lifetime enforcement, allowing authenticated sessions to remain active for extended periods without requiring re-authentication. An attacker with access to a previously authenticated session could continue interacting with administrative functions long after legitimate user activity has ceased.
CWE
  • CWE-613 - Insufficient session expiration
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-25720",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T13:11:05.823674Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T13:11:12.953Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability exists in\u0026nbsp;\u003cspan\u003eSenseLive\u003c/span\u003e\n\nX3050\u2019s web management interface due to improper session lifetime enforcement, allowing authenticated sessions to remain active for extended periods without requiring re-authentication. An attacker with access to a previously authenticated session could continue interacting with administrative functions long after legitimate user activity has ceased."
            }
          ],
          "value": "A vulnerability exists in\u00a0SenseLive\n\nX3050\u2019s web management interface due to improper session lifetime enforcement, allowing authenticated sessions to remain active for extended periods without requiring re-authentication. An attacker with access to a previously authenticated session could continue interacting with administrative functions long after legitimate user activity has ceased."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-613",
              "description": "CWE-613 Insufficient session expiration",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T23:48:16.663Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://senselive.io/contact"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Insufficient session expiration",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-25720",
    "datePublished": "2026-04-23T23:48:16.663Z",
    "dateReserved": "2026-04-14T16:05:54.140Z",
    "dateUpdated": "2026-04-24T13:11:12.953Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-40630 (GCVE-0-2026-40630)

Vulnerability from cvelistv5 – Published: 2026-04-23 23:45 – Updated: 2026-04-24 13:11
VLAI?
Title
SenseLive X3050 Authentication bypass using an alternate path or channel
Summary
A vulnerability in  SenseLive X3050’s web management interface allows unauthorized access to certain configuration endpoints due to improper access control enforcement. An attacker with network access to the device may be able to bypass the intended authentication mechanism and directly interact with sensitive configuration functions.
CWE
  • CWE-288 - Authentication bypass using an alternate path or channel
Assigner
Impacted products
Vendor Product Version
SenseLive X3050 Affected: V1.523
Create a notification for this product.
Credits
Jithin Nambiar J reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-40630",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T13:11:39.609434Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T13:11:46.041Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "X3050",
          "vendor": "SenseLive",
          "versions": [
            {
              "status": "affected",
              "version": "V1.523"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jithin Nambiar J reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-21T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in\u0026nbsp;\nSenseLive \n\nX3050\u2019s web management interface allows unauthorized access to certain configuration endpoints due to improper access control enforcement. An attacker with network access to the device may be able to bypass the intended authentication mechanism and directly interact with sensitive configuration functions."
            }
          ],
          "value": "A vulnerability in\u00a0\nSenseLive \n\nX3050\u2019s web management interface allows unauthorized access to certain configuration endpoints due to improper access control enforcement. An attacker with network access to the device may be able to bypass the intended authentication mechanism and directly interact with sensitive configuration functions."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-288",
              "description": "CWE-288 Authentication bypass using an alternate path or channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T23:45:46.695Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json"
        },
        {
          "url": "https://senselive.io/contact"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact\u0026nbsp;"
            }
          ],
          "value": "SenseLive did not respond to CISA\u0027s requests to coordinate. Affected users are encouraged to reach out to SenseLive for more information. https://senselive.io/contact"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-12",
        "discovery": "EXTERNAL"
      },
      "title": "SenseLive X3050 Authentication bypass using an alternate path or channel",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-40630",
    "datePublished": "2026-04-23T23:45:46.695Z",
    "dateReserved": "2026-04-14T16:05:54.127Z",
    "dateUpdated": "2026-04-24T13:11:46.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-6376 (GCVE-0-2026-6376)

Vulnerability from cvelistv5 – Published: 2026-04-23 20:10 – Updated: 2026-04-24 13:52
VLAI?
Title
Missing authentication for critical function in SpiceJet Online Booking System
Summary
A weakness in SpiceJet’s public booking retrieval page permits full passenger booking details to be accessed using only a PNR and last name, with no authentication or verification mechanisms. This results in exposure of extensive personal, travel, and booking metadata to any unauthenticated user who can obtain or guess those basic inputs. The issue arises from improper access control on a sensitive data retrieval function.
CWE
  • CWE-306 - Missing authentication for critical function
Assigner
Impacted products
Credits
Owais Shaikh reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-6376",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T13:52:36.224906Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T13:52:43.538Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Online Booking System",
          "vendor": "SpiceJet",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Owais Shaikh reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-23T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A weakness in SpiceJet\u2019s public booking retrieval page permits full passenger booking details to be accessed using only a PNR and last name, with no authentication or verification mechanisms. This results in exposure of extensive personal, travel, and booking metadata to any unauthenticated user who can obtain or guess those basic inputs. The issue arises from improper access control on a sensitive data retrieval function."
            }
          ],
          "value": "A weakness in SpiceJet\u2019s public booking retrieval page permits full passenger booking details to be accessed using only a PNR and last name, with no authentication or verification mechanisms. This results in exposure of extensive personal, travel, and booking metadata to any unauthenticated user who can obtain or guess those basic inputs. The issue arises from improper access control on a sensitive data retrieval function."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing authentication for critical function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T20:12:15.862Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-04"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Missing authentication for critical function in SpiceJet Online Booking System",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-6376",
    "datePublished": "2026-04-23T20:10:19.689Z",
    "dateReserved": "2026-04-15T16:31:32.165Z",
    "dateUpdated": "2026-04-24T13:52:43.538Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-6375 (GCVE-0-2026-6375)

Vulnerability from cvelistv5 – Published: 2026-04-23 20:07 – Updated: 2026-04-24 18:19
VLAI?
Title
Authorization bypass through User-Controlled key in SpiceJet Online Booking System
Summary
A vulnerability in SpiceJet’s booking API allows unauthenticated users to query passenger name records (PNRs) without any access controls. Because PNR identifiers follow a predictable pattern, an attacker could systematically enumerate valid records and obtain associated passenger names. This flaw stems from missing authorization checks on an endpoint intended for authenticated profile access.
CWE
  • CWE-639 - Authorization bypass through User-Controlled key
Assigner
Impacted products
Credits
Owais Shaikh reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-6375",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-24T15:51:50.174882Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-24T18:19:59.492Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Online Booking System",
          "vendor": "SpiceJet",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Owais Shaikh reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2026-04-23T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in SpiceJet\u2019s booking API allows unauthenticated users to query passenger name records (PNRs) without any access controls. Because PNR identifiers follow a predictable pattern, an attacker could systematically enumerate valid records and obtain associated passenger names. This flaw stems from missing authorization checks on an endpoint intended for authenticated profile access."
            }
          ],
          "value": "A vulnerability in SpiceJet\u2019s booking API allows unauthenticated users to query passenger name records (PNRs) without any access controls. Because PNR identifiers follow a predictable pattern, an attacker could systematically enumerate valid records and obtain associated passenger names. This flaw stems from missing authorization checks on an endpoint intended for authenticated profile access."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639 Authorization bypass through User-Controlled key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T20:08:10.133Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-04"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Authorization bypass through User-Controlled key in SpiceJet Online Booking System",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-6375",
    "datePublished": "2026-04-23T20:07:23.930Z",
    "dateReserved": "2026-04-15T16:31:31.228Z",
    "dateUpdated": "2026-04-24T18:19:59.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-6074 (GCVE-0-2026-6074)

Vulnerability from cvelistv5 – Published: 2026-04-23 18:14 – Updated: 2026-04-23 18:50
VLAI?
Title
Path traversal: '.../...//' in Intrado 911 Emergency Gateway (EGW)
Summary
A path traversal condition in Intrado 911 Emergency Gateway could allow an attacker with existing network access the ability to access the EGW management interface without authentication. Successful exploitation of this vulnerability could allow a user to read, modify, or delete files.
CWE
  • CWE-35 - Path traversal: '.../...//'
Assigner
References
Impacted products
Vendor Product Version
Intrado 911 Emergency Gateway Affected: Versions 7.x
Affected: Versions 6.x
Affected: Versions 5.x
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-6074",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-23T18:50:08.955110Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-23T18:50:20.955Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "911 Emergency Gateway",
          "vendor": "Intrado",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 7.x"
            },
            {
              "status": "affected",
              "version": "Versions 6.x"
            },
            {
              "status": "affected",
              "version": "Versions 5.x"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA path traversal condition in Intrado 911 Emergency Gateway could allow an attacker with existing network access the ability to access the EGW management interface without authentication. Successful exploitation of this vulnerability could allow a user to read, modify, or delete files.\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "A path traversal condition in Intrado 911 Emergency Gateway could allow an attacker with existing network access the ability to access the EGW management interface without authentication. Successful exploitation of this vulnerability could allow a user to read, modify, or delete files."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-35",
              "description": "CWE-35 Path traversal: \u0027.../...//\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-23T18:14:09.028Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-06"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIntrado developed and released a software update on March 2nd, 2026, that addresses this issue and has contacted customers to coordinate applying the patch.\u003c/p\u003e\u003cp\u003eIf you have questions, contact Intrado E911 Support: E911Support@intrado.com\u003c/p\u003e"
            }
          ],
          "value": "Intrado developed and released a software update on March 2nd, 2026, that addresses this issue and has contacted customers to coordinate applying the patch.\n\nIf you have questions, contact Intrado E911 Support: E911Support@intrado.com"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Path traversal: \u0027.../...//\u0027 in Intrado 911 Emergency Gateway (EGW)",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-6074",
    "datePublished": "2026-04-23T18:14:09.028Z",
    "dateReserved": "2026-04-10T14:14:22.543Z",
    "dateUpdated": "2026-04-23T18:50:20.955Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-1354 (GCVE-0-2026-1354)

Vulnerability from cvelistv5 – Published: 2026-04-21 21:43 – Updated: 2026-04-22 17:51
VLAI?
Title
Zero Motorcycles Firmware Key Exchange without Entity Authentication
Summary
Zero Motorcycles firmware versions 44 and prior enable an attacker to forcibly pair a device with the motorcycle via Bluetooth. Once paired, an attacker can utilize over-the-air firmware updating functionality to potentially upload malicious firmware to the motorcycle. The motorcycle must first be in Bluetooth pairing mode, and the attacker must be in proximity of the vehicle and understand the full pairing process, to be able to pair their device with the vehicle. The attacker's device must remain paired with and in proximity of the motorcycle for the entire duration of the firmware update.
CWE
Assigner
Impacted products
Vendor Product Version
Zero Motorcycles Zero Motorcycles firmware Affected: 0 , ≤ 44 (custom)
Create a notification for this product.
Credits
Persephone Karnstein of Bureau Veritas Cybersecurity North America reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-1354",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-22T17:50:05.706973Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-22T17:51:45.219Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Zero Motorcycles firmware",
          "vendor": "Zero Motorcycles",
          "versions": [
            {
              "lessThanOrEqual": "44",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Persephone Karnstein of Bureau Veritas Cybersecurity North America reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Zero Motorcycles firmware versions 44 and prior enable an attacker to \nforcibly pair a device with the motorcycle via Bluetooth. Once paired, \nan attacker can utilize over-the-air firmware updating functionality to \npotentially upload malicious firmware to the motorcycle. The motorcycle \nmust first be in Bluetooth pairing mode, and the attacker must be in \nproximity of the vehicle and understand the full pairing process, to be \nable to pair their device with the vehicle. The attacker\u0027s device must \nremain paired with and in proximity of the motorcycle for the entire \nduration of the firmware update."
            }
          ],
          "value": "Zero Motorcycles firmware versions 44 and prior enable an attacker to \nforcibly pair a device with the motorcycle via Bluetooth. Once paired, \nan attacker can utilize over-the-air firmware updating functionality to \npotentially upload malicious firmware to the motorcycle. The motorcycle \nmust first be in Bluetooth pairing mode, and the attacker must be in \nproximity of the vehicle and understand the full pairing process, to be \nable to pair their device with the vehicle. The attacker\u0027s device must \nremain paired with and in proximity of the motorcycle for the entire \nduration of the firmware update."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-322",
              "description": "CWE-322",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-21T21:43:53.276Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-06"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-06.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-111-06",
        "discovery": "EXTERNAL"
      },
      "title": "Zero Motorcycles Firmware Key Exchange without Entity Authentication",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Zero Motorcycles has investigated this report and cautions users to pair\n their mobile device to their vehicle in a safe location where they can \nbe sure no one else will try to pair at the same time. Once initiated, \ncomplete the full pairing process and confirm it is successful. Store \nphysical keys in a secure location and do not leave the bike unattended \nwith the key in the \"ON\" position. Zero Motorcycles plans to address \nthis issue in a firmware update scheduled for release in May 2026. \nUpdate the firmware to the latest available version."
            }
          ],
          "value": "Zero Motorcycles has investigated this report and cautions users to pair\n their mobile device to their vehicle in a safe location where they can \nbe sure no one else will try to pair at the same time. Once initiated, \ncomplete the full pairing process and confirm it is successful. Store \nphysical keys in a secure location and do not leave the bike unattended \nwith the key in the \"ON\" position. Zero Motorcycles plans to address \nthis issue in a firmware update scheduled for release in May 2026. \nUpdate the firmware to the latest available version."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-1354",
    "datePublished": "2026-04-21T21:43:53.276Z",
    "dateReserved": "2026-01-22T18:31:58.496Z",
    "dateUpdated": "2026-04-22T17:51:45.219Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-32650 (GCVE-0-2026-32650)

Vulnerability from cvelistv5 – Published: 2026-04-17 19:52 – Updated: 2026-04-17 20:26
VLAI?
Title
Anviz CrossChex Standard Algorithm Downgrade
Summary
Anviz CrossChex Standard is vulnerable when an attacker manipulates the TDS7 PreLogin to disable encryption, causing database credentials to be sent in plaintext and enabling unauthorized database access.
CWE
Assigner
Impacted products
Vendor Product Version
Anviz Anviz CrossChex Standard Affected: All versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-32650",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-17T20:26:08.787769Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-17T20:26:17.922Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CrossChex Standard",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz CrossChex Standard\u0026nbsp;is vulnerable when an attacker manipulates the TDS7 PreLogin to disable \nencryption, causing database credentials to be sent in plaintext and \nenabling unauthorized database access."
            }
          ],
          "value": "Anviz CrossChex Standard\u00a0is vulnerable when an attacker manipulates the TDS7 PreLogin to disable \nencryption, causing database credentials to be sent in plaintext and \nenabling unauthorized database access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-757",
              "description": "CWE-757",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-17T19:52:45.308Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.anviz.com/contact-us.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-03.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-106-03",
        "discovery": "EXTERNAL"
      },
      "title": "Anviz CrossChex Standard Algorithm Downgrade",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
            }
          ],
          "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-32650",
    "datePublished": "2026-04-17T19:52:45.308Z",
    "dateReserved": "2026-04-14T15:42:14.116Z",
    "dateUpdated": "2026-04-17T20:26:17.922Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-40434 (GCVE-0-2026-40434)

Vulnerability from cvelistv5 – Published: 2026-04-17 19:49 – Updated: 2026-04-17 20:28
VLAI?
Title
Anviz CrossChex Standard Improper Verification of Source of a Communication Channel
Summary
Anviz CrossChex Standard lacks source verification in the client/server channel, enabling TCP packet injection by an attacker on the same network to alter or disrupt application traffic.
CWE
Assigner
Impacted products
Vendor Product Version
Anviz Anviz CrossChex Standard Affected: All versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-40434",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-17T20:27:23.496359Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-17T20:28:02.785Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CrossChex Standard",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz CrossChex Standard\nlacks source verification in the client/server channel, enabling TCP \npacket injection by an attacker on the same network to alter or disrupt \napplication traffic."
            }
          ],
          "value": "Anviz CrossChex Standard\nlacks source verification in the client/server channel, enabling TCP \npacket injection by an attacker on the same network to alter or disrupt \napplication traffic."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-940",
              "description": "CWE-940",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-17T19:49:28.099Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.anviz.com/contact-us.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-03.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-106-03",
        "discovery": "EXTERNAL"
      },
      "title": "Anviz CrossChex Standard Improper Verification of Source of a Communication Channel",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
            }
          ],
          "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-40434",
    "datePublished": "2026-04-17T19:49:28.099Z",
    "dateReserved": "2026-04-14T15:42:14.096Z",
    "dateUpdated": "2026-04-17T20:28:02.785Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-35682 (GCVE-0-2026-35682)

Vulnerability from cvelistv5 – Published: 2026-04-17 19:46 – Updated: 2026-04-17 20:30
VLAI?
Title
Anviz CX2 Lite Command Injection
Summary
Anviz CX2 Lite is vulnerable to an authenticated command injection via a filename parameter that enables arbitrary command execution (e.g., starting telnetd), resulting in root‑level access.
CWE
Assigner
Impacted products
Vendor Product Version
Anviz Anviz CX2 Lite Firmware Affected: All versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-35682",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-17T20:30:04.932110Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-17T20:30:18.510Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX2 Lite Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz\u0026nbsp;CX2 Lite is vulnerable to an authenticated command injection via a \nfilename parameter that enables arbitrary command execution (e.g., \nstarting telnetd), resulting in root\u2011level access."
            }
          ],
          "value": "Anviz\u00a0CX2 Lite is vulnerable to an authenticated command injection via a \nfilename parameter that enables arbitrary command execution (e.g., \nstarting telnetd), resulting in root\u2011level access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-17T19:46:26.716Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.anviz.com/contact-us.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-03.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-106-03",
        "discovery": "EXTERNAL"
      },
      "title": "Anviz CX2 Lite Command Injection",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
            }
          ],
          "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-35682",
    "datePublished": "2026-04-17T19:46:26.716Z",
    "dateReserved": "2026-04-14T15:47:54.211Z",
    "dateUpdated": "2026-04-17T20:30:18.510Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-40066 (GCVE-0-2026-40066)

Vulnerability from cvelistv5 – Published: 2026-04-17 19:43 – Updated: 2026-04-17 20:00
VLAI?
Title
Anviz Products Download of Code Without Integrity Check
Summary
Anviz CX2 Lite and CX7 are vulnerable to unverified update packages that can be uploaded. The device unpacks and executes a script resulting in unauthenticated remote code execution.
CWE
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-40066",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-17T20:00:10.096399Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-17T20:00:36.786Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX7 Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX2 Lite Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz\u0026nbsp;CX2 Lite and CX7\u0026nbsp;are vulnerable to unverified update packages that can be uploaded. The \ndevice unpacks and executes a script resulting in unauthenticated remote\n code execution."
            }
          ],
          "value": "Anviz\u00a0CX2 Lite and CX7\u00a0are vulnerable to unverified update packages that can be uploaded. The \ndevice unpacks and executes a script resulting in unauthenticated remote\n code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-494",
              "description": "CWE-494",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-17T19:43:20.709Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.anviz.com/contact-us.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-03.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-106-03",
        "discovery": "EXTERNAL"
      },
      "title": "Anviz Products Download of Code Without Integrity Check",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
            }
          ],
          "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-40066",
    "datePublished": "2026-04-17T19:43:20.709Z",
    "dateReserved": "2026-04-14T15:47:54.264Z",
    "dateUpdated": "2026-04-17T20:00:36.786Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-35546 (GCVE-0-2026-35546)

Vulnerability from cvelistv5 – Published: 2026-04-17 19:39 – Updated: 2026-04-17 20:05
VLAI?
Title
Anviz Products Missing Authentication for Critical Function
Summary
Anviz CX2 Lite and CX7 are vulnerable to unauthenticated firmware uploads. This causes crafted archives to be accepted, enabling attackers to plant and execute code and obtain a reverse shell.
CWE
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-35546",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-17T20:05:03.369768Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-17T20:05:28.411Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX7 Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX2 Lite Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz\u0026nbsp;CX2 Lite and CX7\u0026nbsp;are vulnerable to unauthenticated firmware uploads. This causes crafted \narchives to be accepted, enabling attackers to plant and execute code \nand obtain a reverse shell."
            }
          ],
          "value": "Anviz\u00a0CX2 Lite and CX7\u00a0are vulnerable to unauthenticated firmware uploads. This causes crafted \narchives to be accepted, enabling attackers to plant and execute code \nand obtain a reverse shell."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-17T19:39:25.110Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.anviz.com/contact-us.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-03.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-106-03",
        "discovery": "EXTERNAL"
      },
      "title": "Anviz Products Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
            }
          ],
          "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-35546",
    "datePublished": "2026-04-17T19:39:25.110Z",
    "dateReserved": "2026-04-14T15:47:54.234Z",
    "dateUpdated": "2026-04-17T20:05:28.411Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-40461 (GCVE-0-2026-40461)

Vulnerability from cvelistv5 – Published: 2026-04-17 19:36 – Updated: 2026-04-17 20:03
VLAI?
Title
Anviz Products Missing Authentication for Critical Function
Summary
Anviz CX2 Lite and CX7 are vulnerable to unauthenticated POST requests that modify debug settings (e.g., enabling SSH), allowing unauthorized state changes that can facilitate later compromise.
CWE
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-40461",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-17T20:02:41.120773Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-17T20:03:18.872Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX7 Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX2 Lite Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz\u0026nbsp;CX2 Lite and CX7\u0026nbsp;are vulnerable to unauthenticated POST requests that modify debug \nsettings (e.g., enabling SSH), allowing unauthorized state changes that \ncan facilitate later compromise."
            }
          ],
          "value": "Anviz\u00a0CX2 Lite and CX7\u00a0are vulnerable to unauthenticated POST requests that modify debug \nsettings (e.g., enabling SSH), allowing unauthorized state changes that \ncan facilitate later compromise."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-17T19:36:29.842Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.anviz.com/contact-us.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-03.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-106-03",
        "discovery": "EXTERNAL"
      },
      "title": "Anviz Products Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
            }
          ],
          "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-40461",
    "datePublished": "2026-04-17T19:36:29.842Z",
    "dateReserved": "2026-04-14T15:52:06.314Z",
    "dateUpdated": "2026-04-17T20:03:18.872Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-32648 (GCVE-0-2026-32648)

Vulnerability from cvelistv5 – Published: 2026-04-17 19:34 – Updated: 2026-04-17 20:09
VLAI?
Title
Anviz Products Missing Authorization
Summary
Anviz CX2 Lite and CX7 are vulnerable to unauthenticated access that discloses debug configuration details (e.g., SSH/RTTY status), assisting attackers in reconnaissance against the device.
CWE
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-32648",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-17T20:08:33.345711Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-17T20:09:05.861Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX7 Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX2 Lite Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz\u0026nbsp;CX2 Lite and CX7\u0026nbsp;are vulnerable to unauthenticated access that discloses debug \nconfiguration details (e.g., SSH/RTTY status), assisting attackers in \nreconnaissance against the device."
            }
          ],
          "value": "Anviz\u00a0CX2 Lite and CX7\u00a0are vulnerable to unauthenticated access that discloses debug \nconfiguration details (e.g., SSH/RTTY status), assisting attackers in \nreconnaissance against the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "CWE-862",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-17T19:34:21.522Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.anviz.com/contact-us.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-03.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-106-03",
        "discovery": "EXTERNAL"
      },
      "title": "Anviz Products Missing Authorization",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
            }
          ],
          "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-32648",
    "datePublished": "2026-04-17T19:34:21.522Z",
    "dateReserved": "2026-04-14T15:52:06.301Z",
    "dateUpdated": "2026-04-17T20:09:05.861Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-33569 (GCVE-0-2026-33569)

Vulnerability from cvelistv5 – Published: 2026-04-17 19:30 – Updated: 2026-04-17 20:32
VLAI?
Title
Anviz Products Cleartext Transmission of Sensitive Information
Summary
Anviz CX2 Lite and CX7 administrative sessions occur over HTTP, enabling on‑path attackers to sniff credentials and session data, which can be used to compromise the device.
CWE
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-33569",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-17T20:32:31.417281Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-17T20:32:48.104Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX7 Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Anviz CX2 Lite Firmware",
          "vendor": "Anviz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz\u0026nbsp;CX2 Lite and CX7 administrative sessions occur over HTTP, enabling \non\u2011path attackers to sniff credentials and session data, which can be \nused to compromise the device."
            }
          ],
          "value": "Anviz\u00a0CX2 Lite and CX7 administrative sessions occur over HTTP, enabling \non\u2011path attackers to sniff credentials and session data, which can be \nused to compromise the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-17T19:30:46.066Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.anviz.com/contact-us.html"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-106-03"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-106-03.json"
        }
      ],
      "source": {
        "advisory": "ICSA-26-106-03",
        "discovery": "EXTERNAL"
      },
      "title": "Anviz Products Cleartext Transmission of Sensitive Information",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
            }
          ],
          "value": "Anviz did not respond to CISA\u0027s attempts to coordinate these \nvulnerabilities. Users should contact Anviz for more information at \nhttps://www.anviz.com/contact-us.html."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-33569",
    "datePublished": "2026-04-17T19:30:46.066Z",
    "dateReserved": "2026-04-14T15:42:14.069Z",
    "dateUpdated": "2026-04-17T20:32:48.104Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",