CVE-2024-29207 (GCVE-0-2024-29207)

Vulnerability from cvelistv5 – Published: 2024-05-07 16:40 – Updated: 2024-08-02 01:10
VLAI?
Summary
An Improper Certificate Validation could allow a malicious actor with access to an adjacent network to take control of the system. Affected Products: UniFi Connect Application (Version 3.7.9 and earlier) UniFi Connect EV Station (Version 1.1.18 and earlier) UniFi Connect EV Station Pro (Version 1.1.18 and earlier) UniFi Connect Display (Version 1.9.324 and earlier) UniFi Connect Display Cast (Version 1.6.225 and earlier) Mitigation: Update UniFi Connect Application to Version 3.10.7 or later. Update UniFi Connect EV Station to Version 1.2.15 or later. Update UniFi Connect EV Station Pro to Version 1.2.15 or later. Update UniFi Connect Display to Version 1.11.348 or later. Update UniFi Connect Display Cast to Version 1.8.255 or later.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ubiquiti:unifi_connect_display_cast:1.8.255:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unifi_connect_display_cast",
            "vendor": "ubiquiti",
            "versions": [
              {
                "status": "affected",
                "version": "1.8.255"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:ubiquiti:unifi_connect_display:1.11.348:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unifi_connect_display",
            "vendor": "ubiquiti",
            "versions": [
              {
                "status": "affected",
                "version": "1.11.348"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:ubiquiti:unifi_connect_application:3.10.7:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unifi_connect_application",
            "vendor": "ubiquiti",
            "versions": [
              {
                "status": "affected",
                "version": "3.10.7"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:ubiquiti:unifi_connect_ev_station:1.2.15:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unifi_connect_ev_station",
            "vendor": "ubiquiti",
            "versions": [
              {
                "status": "affected",
                "version": "1.2.15 "
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:ubiquiti:unifi_connect_ev_station_pro:1.2.15.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unifi_connect_ev_station_pro",
            "vendor": "ubiquiti",
            "versions": [
              {
                "status": "affected",
                "version": "1.2.15.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29207",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-07T19:34:11.302957Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:46.353Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:55.406Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://community.ui.com/releases/Security-Advisory-bulletin-039-039/44e24007-2c2c-4ac0-bebf-3f19b9b24f09"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "UniFi Connect Application",
          "vendor": "Ubiquiti Inc",
          "versions": [
            {
              "lessThan": "3.10.7",
              "status": "affected",
              "version": "3.10.7",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "UniFi Connect EV Station",
          "vendor": "Ubiquiti Inc",
          "versions": [
            {
              "lessThan": "1.2.15",
              "status": "affected",
              "version": "1.2.15",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "UniFi Connect EV Station Pro ",
          "vendor": "Ubiquiti Inc",
          "versions": [
            {
              "lessThan": "1.2.15",
              "status": "affected",
              "version": "1.2.15",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "UniFi Connect Display",
          "vendor": "Ubiquiti Inc",
          "versions": [
            {
              "lessThan": "1.11.348",
              "status": "affected",
              "version": "1.11.348",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "UniFi Connect Display Cast",
          "vendor": "Ubiquiti Inc",
          "versions": [
            {
              "lessThan": "1.8.255",
              "status": "affected",
              "version": "1.8.255",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Certificate Validation could allow a malicious actor with access to an adjacent network to take control of the system. \n\n \n\nAffected Products:\n\nUniFi Connect Application (Version 3.7.9 and earlier) \n\nUniFi Connect EV Station (Version 1.1.18 and earlier) \n\nUniFi Connect EV Station Pro (Version 1.1.18 and earlier)\n\nUniFi Connect Display (Version 1.9.324 and earlier)\n\nUniFi Connect Display Cast (Version 1.6.225 and earlier)\n\n \n\nMitigation:\n\nUpdate UniFi Connect Application to Version 3.10.7 or later.\n\nUpdate UniFi Connect EV Station to Version 1.2.15 or later.\n\nUpdate UniFi Connect EV Station Pro to Version 1.2.15 or later.\n\nUpdate UniFi Connect Display to Version 1.11.348 or later.\n\nUpdate UniFi Connect Display Cast to Version 1.8.255 or later.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-07T16:40:02.502Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "url": "https://community.ui.com/releases/Security-Advisory-bulletin-039-039/44e24007-2c2c-4ac0-bebf-3f19b9b24f09"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2024-29207",
    "datePublished": "2024-05-07T16:40:02.502Z",
    "dateReserved": "2024-03-19T01:04:06.323Z",
    "dateUpdated": "2024-08-02T01:10:55.406Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…